DETERMINATION OF OXALIC ACID
AND OXALATES USING
MODIFIED FILM ELECTRODES.
CECILIA CRISTEA1, LIVIU ROMAN1, ROBERT SĂNDULESCU1, I.O. MARIAN2
1University of Medicine and Pharmacy “Iuliu Haţieganu”, Faculty of Pharmacy, Department of Analytical Chemistry, 4 Pasteur str, 400 349 Cluj-Napoca, Romania
2“Babeş-Bolyai” University, Faculty of Chemistry and Chemical Engineering, Department of Physical-Chemistry, 11 Arany Janos str, Cluj-Napoca, Romania
Abstract:
Modified film electrodes represent novel and useful analytical devices capable to offer a fast and reliable response, with improve selectivity and sensitivity over other electroanalytical techniques. The detection of oxalic acid and its oxalate is of interest in biomedical analysis but also in food, paper and drug analysis. Two electroanalytical methods are presented for the detection of oxalic acid, cyclic voltammetry and potentiometric titration using Hg film electrodes
.